The flameproof principle accepts that gas may enter an enclosure and ignite, but contains the explosion safely.
Flameproof enclosures are not gas tight, and a gas or vapour will enter the enclosure through joints or cable entries. Since these enclosures are designed to contain components which are an ignition source, ignition of the gas may occur, and the resulting explosion pressure can reach a peak value in excess of 10 Bar (150psi). IIC gases have a greater explosion pressure than IIB or IIA gases, typically up to 13 Bar for hydrogen).
The enclosure must therefore be strong enough to contain this explosion pressure, and the gaps at the joints and threads of cable entries must be long and narrow to help cool the flames/ hot gases to prevent transmission of the internal explosion to a flammable atmosphere outside the enclosure.
What the flameproof principle means for users #
Because flameproof enclosures are not gas tight, it is normal for gas to enter them. Safety therefore depends on two things that users can affect. First, the enclosure must keep its strength, so covers, bolts and walls must be in good condition. Second, the flamepaths must stay clean, undamaged and correctly sized, so they can cool any escaping gases.
Explosion pressures are highest for IIC gases such as hydrogen, which is why IIC enclosures are built and tested to tighter requirements. Equipment must therefore be used only in the gas groups shown on its label. In addition, the external surface temperature must stay below the ignition temperature of the gas.
For more detail, read flameproof enclosure construction and pressure piling. AZUVIA’s explosion-proof rectifiers use recognised protection concepts for hazardous areas. Flameproof design is covered by IEC 60079-1, published by IEC.