Forced Air-Cooled Rectifiers

Rectified Power SystemsClean DC for indoor, safe-area installations.

This forced air-cooled rectifier range converts AC into precise DC for industrial loads installed in safe, ventilated rooms.

Electronically controlled thyristor rectifiers integrated in a robust steel frame housing with front and back door

AZUVIA forced air-cooled rectifiers use thyristor-controlled rectification in a ventilated steel cabinet, with fans drawing air across the transformer and heat sinks. They are the simplest and most economical choice for indoor, safe-area installations such as engine rooms, pump houses and electrical rooms.

System OverviewWhy choose an air-cooled rectifier

  • Environmentally-friendly
  • Compact design
  • Low-wear control
  • High control precision
  • High control speed
  • Maintenance-friendly assembly
  • Low maintenance requirement

How an air-cooled rectifier works

Forced air cooling suits clean, dry rooms with a stable ambient temperature. Where the air is humid, salty or dusty, an oil-immersed or water-cooled design is usually the better choice.

Modern rectifier control

Every rectifier uses a modern logic controller for precise regulation.

  • High-resolution TFT LCD screen
  • Advanced monitoring with alerts by SMS or email
  • Communication with other systems via Modbus, Profinet and more

Models

Customised Transformer Rectifier

  • Mains voltage: 220 – 690V, 50 – 60 Hz, 3-phase
  • DC voltage: 6 – 400 Volt
  • DC current: 2000 – 80000 Ampere
  • Regulation: current and voltage constant
  • Control range: 0 – 100 %
  • Regulation accuracy: ±1 %
  • Efficiency: > 85 %
  • Ripple: 5 – 7 % at max. rating (Reduction possible)
  • Mode of operation: 100 % ED (Power-on time)
  • Ambient temperature: + 35 °C (higher temp on request)
  • Protection class: IP 20 to IP 54

PS1K Transformer Rectifier

  • Mains voltage: 440V, 60 Hz, 3-phase
  • DC voltage: 15 Volt
  • DC current: 440 Ampere
  • Regulation: Current constant
  • Control range: 0 – 100 %
  • Regulation accuracy: ±1 %
  • Efficiency: > 85 %
  • Ripple: 5 – 7 % at max. rating (Reduction possible)
  • Mode of operation: 100 % ED (Power-on time)
  • Ambient temperature: + 35 °C (higher temp on request)
  • Protection class: IP 44

PS3K Transformer Rectifier

  • Mains voltage: 440V, 60 Hz, 3-phase
  • DC voltage: 45 Volt
  • DC current: 440 Ampere
  • Regulation: Current constant
  • Control range: 0 – 100 %
  • Regulation accuracy: ±1 %
  • Efficiency: > 85 %
  • Ripple: 5 – 7 % at max. rating (Reduction possible)
  • Mode of operation: 100 % ED (Power-on time)
  • Ambient temperature: + 35 °C (higher temp on request)
  • Protection class: IP 44

PS6K Transformer Rectifier

  • Mains voltage: 440V, 60 Hz, 3-phase
  • DC voltage: 75 Volt
  • DC current: 440 Ampere
  • Regulation: Current constant
  • Control range: 0 – 100 %
  • Regulation accuracy: ±1 %
  • Efficiency: > 85 %
  • Ripple: 5 – 7 % at max. rating (Reduction possible)
  • Mode of operation: 100 % ED (Power-on time)
  • Ambient temperature: + 35 °C (higher temp on request)
  • Protection class: IP 44