Electrochlorination process chemistry links seawater flow, DC current and electrolyser arrangement to the hypochlorite produced.
The primary equipment items for an Electrochlorination Package consist of seawater Electrolyser(s) and DC current supplies generally in the form of AC Transformers complete with Thyristor Rectifier assemblies…
Typically an electrolyser stream will be fed DC current from one transformer rectifier, with the electrolyser stream consisting of between 1 and 4 electrolysers. The electrolysers in one stream will be in hydraulic and electrical series wherein additional product weight is produced in each electrolyser which is progressively taken into solution within the stream seawater carrier stream to achieve the design hypochlorite concentration / weight at the electrolyser stream discharge.
NaOCl kg/h = Seawater Flowrate m3/h x mg/l (NaOCl)
1000
The electrolyser(s) stream will be selected for optimum capital equipment and consumable costs by the supplier and the following criteria apply in this process. Any number of electrolyser streams can operate in parallel.
How electrochlorination process chemistry works #
At the anode, chloride ions in seawater or brine lose electrons and form chlorine. At the cathode, water is split into hydrogen gas and hydroxide. Because the two products mix in an undivided cell, the chlorine reacts immediately with hydroxide to form sodium hypochlorite. The result is a dilute hypochlorite solution, carried away by the seawater stream.
In practice, the process chemistry sets three design rules. First, output is proportional to DC current, so a rectifier controls production. Second, each electrolyser stream adds hypochlorite as it passes through cells in series, so the concentration rises along the train. Third, calcium and magnesium in seawater deposit on the cathodes, which is why some cells need periodic acid cleaning.
With the formula above, you can convert any seawater flow and target concentration into kg/h of hypochlorite. Next, read DC current requirement and electrode sizing to see how that output is turned into hardware. For complete systems, see our electrochlorination range. The IMO biofouling guidance explains why this matters for ships.