Skip to main content

AZUVIA

Powering Possibilities, Innovating Boundaries

Docs Category: Flameproof (Ex d)

Flameproof (Ex d)

Flameproof protection, Ex d, contains any internal explosion so that it cannot ignite the surrounding atmosphere. Introduction to Flameproof (Ex d) Flameproof protection is one of the original methods of explosion protection developed for use in mining industry. It has a…

Read More

EPL of Ex d Equipment

The Ex d EPL is normally db, which makes flameproof equipment suitable for Zones 1 and 2. Generally, Ex d equipment will have a level of protection “db” (EPL: Mb or Gb). This means that this equipment can be used in…

Read More

Principle of Operation

The flameproof principle accepts that gas may enter an enclosure and ignite, but contains the explosion safely. Flameproof enclosures are not gas tight, and a gas or vapour will enter the enclosure through joints or cable entries. Since these enclosures are…

Read More

Construction

Flameproof enclosure construction relies on strong walls and narrow flamepaths that cool escaping gases. Introduction Typical materials used for the construction of flameproof equipment include cast iron and aluminium alloys. Where corrosion resistance is required, gun metal bronze, phosphor bronze and…

Read More

Entries

Flameproof entries must keep the enclosure flameproof where cables and conduits pass through its walls. Cylindrical Threads The threaded part shall be at least 8mm in length (for enclosures > 100mm3), and must have at least 5 full threads as per…

Read More

Obstruction to Flamepaths

Obstruction to flamepaths can stop a flameproof joint cooling escaping gases, so minimum clearances apply. IEC / BS EN60079-14 states that the obstruction of flanged joints must be avoided, unless the equipment has been tested at smaller distances than those shown…

Read More

Fixing removable covers and fasteners

Flameproof cover fasteners must all be fitted and tight, because the enclosure’s strength depends on them. All cover fixing bolts must be fitted and fastened down “ Spanner tight” at all times, wherever the equipment could possibly be energised, even during…

Read More

Protection

Flameproof electrical protection is essential because Ex d enclosures are tested against gas explosions, not internal short circuits. Electrical Protection Flameproof enclosures are tested for their ability to withstand internal gas explosions only; they are not capable of withstanding the energy…

Read More

Ingress Protection Methods

Ingress protection methods for flameproof equipment keep out water and dust without damaging the flamepaths. The diagrams illustrate typical locations of gaskets or rubber ‘O’ rings for ensuring a high level of ingress protection. The gasket etc. must be an integral…

Read More

Pressure Piling

Pressure piling occurs when an explosion pre-compresses gas in another part of an enclosure, causing a much higher secondary pressure. If a flammable mixture is compressed prior to ignition, the resulting explosion pressure will be considerably higher than if the same…

Read More

Modification of Flameproof Enclosures

Any modification of flameproof enclosures can invalidate their certification and make them unsafe. Flameproof enclosures are supplied complete with all internal components fitted and certified as a single entity by a recognised test authority. The testing procedure will take into account…

Read More