Intrinsic safety levels of protection ia, ib and ic set how many faults equipment can tolerate and where it may be used.
| Level of protection | EPL | ATEX Category | Zones of use ** |
| Ia | Ga | 1G | Zones 0,1 & 2 |
| Ib | Gb | 2G | Zones 1 and 2 |
| Ic | Gc | 3G | Zone 2 only |
** Unless a risk assessment, taking into account the possible consequences of an explosion, has called for the use of a higher or lower level of protection.
Level of protection ‘ia’
‘ia’ has the highest integrity, and must remain incapable of causing ignition in normal operation with maximum rated voltage applied, even with two ‘countable’ faults, as defined in the standards.
‘ia’ may be used in locations requiring EPL Ga, Gb & Gc (Cat’s 1G, 2G, & 3G).
Level of protection ‘ib’
‘ib’ must remain incapable of causing ignition in normal operation with maximum rated voltage applied, even with one ‘countable’ faults, as defined in the standards.
‘ib’ equipment may be used in locations requiring EPL’s Gb & Gc (Cat’s 2G, & 3G).
Level of protection ‘ic’
‘ic’ must remain incapable of causing ignition in normal operation with maximum rated voltage applied
‘ic’ equipment may only be used in locations requiring EPL “Gc” / Category 3.
Selecting intrinsic safety levels of protection #
Start with the area classification. If the drawing shows the required EPL, choose a level that meets it: ia for Ga, ib for Gb and ic for Gc. If only zones are shown, the usual mapping applies, with ia for Zone 0, ib for Zone 1 and ic for Zone 2, unless a risk assessment justifies a different choice.
Remember that the level of a loop is set by its weakest item. An ia field device connected to an ib barrier forms an ib loop, so it may not be used in Zone 0. In addition, ic equipment is assessed only in normal operation, which makes it simpler and cheaper but limits it to Zone 2.
These levels also appear in the marking, for example Ex ia IIC T4 Ga. For marking and parameters, read intrinsic safety marking and IS parameters. The levels are defined in IEC 60079-11, published by IEC.