This summary of type n equipment variations shows how nA, nC, nL and nR relate to newer protection codes.
This table summarises the variations in Type ‘n’ Equipment
| Type ‘n’ equipment variation | Marking |
| Energy limited equipment | “nL” replaced by ‘ic’ |
| Protected sparking Includes devices protected by: sealing, hermetic-sealing, enclosed-break and non-incendive methods | “nC” encapsulation replaced by ‘mc’ and enclosed break replaced by “dc”. |
| Non-sparking equipment | “nA” is replaced by “ec” |
| Restricted breathing enclosures | “nR” |
What the type n equipment variations mean today #
Type n originally grouped several Zone 2 techniques under one standard, IEC 60079-15. Over recent editions, most of them have moved into the standards for the main protection concepts, as a lower level of protection. As a result, you will see both the old and new codes on equipment in service.
Non-sparking equipment, nA, is now covered by increased safety as level ec. Energy-limited equipment, nL, has become intrinsic safety level ic. Enclosed-break devices from nC have moved to flameproof level dc, and encapsulated parts to level mc. Restricted breathing, nR, remains under the type n standard.
For installers, the practical message is that the old and new codes give equivalent protection for Zone 2, provided the equipment is installed to its certificate. For more detail, read type n protection, type n marking and type n additional protection. The standards are available from IEC.