Externally mounted equipment on a pressurised enclosure must be protected for the zone in which the enclosure sits.
Electrical equipment mounted on the exterior of a pressurised enclosure must be explosion protected in accordance with the Zone (or EPL requirement) in which the enclosure is situated. Typical examples are pressure/flow rate sensors or switches which may use Ex i equipment, and junction boxes using Ex d, Ex e or Ex n methods of protection. This requirement also applies to the motor and starter of the fan which provides the flow of air, unless they are situated in a non-hazardous area (which is preferable).
Selecting externally mounted equipment #
Pressurisation protects only what is inside the enclosure. Anything fixed to the outside, from pressure switches to junction boxes, sits in the surrounding atmosphere and must therefore be protected for that zone in its own right. This is easy to overlook when a pressurised package arrives fully assembled.
Common choices are intrinsically safe sensors and switches, and junction boxes using flameproof, increased safety or type n protection. The purge fan motor and its starter must also be protected if they are in the hazardous area, although placing them in a safe area is better, because it also keeps the air intake away from flammable gas.
During inspection, check each external item against the zone, gas group and temperature class, just as you would for stand-alone equipment. For related topics, read pressurisation ducts and protective gas. Selection rules come from IEC 60079-14, published by IEC.