Pressurised equipment keeps flammable gas out by holding a protective gas inside the enclosure above outside pressure. Introduction Pressurisation is a simple explosion protection technique. If the interior of an enclosure is at a pressure slightly above that externally, any flammable…
Applications
Pressurisation applications range from small instrument cabinets to large motors and whole control rooms. Pressurisation can provide explosion protection for a wide range of instrumentation or electrical equipment – there is no limit to size, within reason, which can be accommodated….
Types of pressurisation and EPL
The types of pressurisation px, py and pz differ in how far they reduce the hazard inside the enclosure. Type pxb is a type of pressurised enclosure that provides an equipment protection level Gb (or Mb or Db). This means that…
Principles of Operation
The principles of pressurisation rely on keeping an enclosure slightly above outside pressure so flammable gas cannot enter. The basic principle of operation involves raising and maintaining the internal pressure of the enclosure to a level slightly above the atmospheric pressure…
Purging
Purging removes any flammable gas from a pressurised enclosure before its electrical equipment is energised. Purging involves passing a specified quantity of the safe gas through the enclosure in order to remove any flammable gases which may have entered. The standards…
Protective Gas
The protective gas keeps flammable gas out of a pressurised enclosure, so its source and quality are critical. The protective gas is normally air, but for certain applications may be an inert gas such as nitrogen. When air is the protective…
Ducts
Pressurisation ducts carry protective gas into and out of the enclosure and must be routed and built with care. Ducts The entry of the inlet duct should be positioned in a non-hazardous location wherever possible (unless from cylinders). The exhaust duct,…
Pressurised Enclosures
Pressurised enclosures must be strong, well sealed and interlocked so that overpressure is reliably maintained. The minimum IP rating for pressurised enclosures is IP4X (IP 3X for alarmed pz enclosures), Not all enclosures are suitable for pressurisation, but the seals may…
Controls & Safety Devices
Pressurisation safety devices monitor overpressure and flow so the enclosure is only energised when it is safe. The level of overpressure will be monitored by a pressure sensor or switch located in the enclosure,at the most difficult point at which to…
Techniques of Pressurisation
There are three main techniques of pressurisation: static, leakage compensation and continuous flow. The applicable pressurising techniques depend upon the condition and on the constituents of the release as follows: Static pressurisation. Pressurisation with continuous flow; Pressurisation with leakage compensation; Pressurisation…
Action on Loss of Pressure
The required action on loss of pressure depends on the zone and on what equipment is inside the pressurised enclosure. No internal source of release The over-pressure within the enclosure is monitored by a pressure switch/sensor, and a flow-rate switch/sensor, located…
Externally Mounted Electrical Equipment
Externally mounted equipment on a pressurised enclosure must be protected for the zone in which the enclosure sits. Electrical equipment mounted on the exterior of a pressurised enclosure must be explosion protected in accordance with the Zone (or EPL requirement) in…
Equipment Energised During Absence of Overpressure
Equipment energised without overpressure must have its own explosion protection because pressurisation no longer protects it. An anti-condensation heater may be used in a rotating electrical machine to prevent internal surfaces and atmosphere becoming cold, thereby preventing the formation of moisture…
Temperature Limits
Pressurisation temperature limits decide the temperature class of a pressurised enclosure and its internal components. Type px or type py pressurisation The temperature class shall be based on the higher of the hottest external surface of the enclosure or the hottest…
Marking
Pressurisation marking shows the type of pressurisation used and whether a control system is associated equipment. The equipment marking must be to IEC 60079-2 & IEC 60079-0, and contain the following information: The manufacturers name Model number, type and serial number…