Docs Category: Wiring Systems & Installation

Standards

Several wiring installation standards apply to hazardous areas, led by IEC 60079-14 for design, selection and erection. IEC 60079-0: 2011 Explosive atmospheres: Part 0. General Requirements. IEC 60079-14: 2007 Explosive atmospheres: Part 14. Electrical installations design, selection and erection IEC 60079-14:…

Read More

Competent Persons

Competent persons are the only people who should select, install or maintain electrical equipment in hazardous areas. Technicians, or operatives as they are called in the IEC60079-14 standard, are required to have sufficient knowledge to achieve the correct selection and installation…

Read More

Cables

Hazardous area cables must suit the zone, the protection concept and the conditions they will meet in service. Electrical equipment in hazardous areas may be weird using cable having metallic or non-metallic sheath, or weird in conduit. Today, cable is generally…

Read More

Fixed Equipment in Zones 1 and 2

Fixed equipment in Zones 1 and 2 must be selected and installed to match the zone, gas group and temperature class. IEC 60079-14 specifies the cable requirements for fixed equipment in Zone 1 & 2. Cables sheathed with thermoplastic, thermosetting or…

Read More

Jointing of Cables

Jointing of cables in hazardous areas should be avoided where possible and, when needed, must keep the installation safe. In hazardous areas, wherever possible, cable runs should be continuous and without interruption. Where discontinuity cannot be avoided, the joint, in addition…

Read More

Cold Flow

Cold flow in cables is the slow creep of some insulation materials under pressure, which can loosen cable glands in hazardous areas. Certain materials used in the manufacture of cables are susceptible to a condition known as ‘cold flow’. Cold flow…

Read More

Cable Glands

Ex cable glands maintain the type of protection where cables enter equipment in a hazardous area. Cable glands are used when terminating cables into electrical equipment. They must be selected according to the methods of explosion protection employed and the environmental…

Read More

Other installation requirements

These hazardous area installation requirements cover cable routing, unused cores, conductor ends and intrinsically safe cabling. Particular IEC60079-14 installation requirements from the standards Cables and terminations: Cable routing. Where cables pass from one safe area to another via a hazardous area,…

Read More

Restriction of Installation

Restriction of installation rules limit where and how electrical equipment and wiring may be placed in hazardous areas. Types of lamps in Ex e and Ex n luminaires There are restrictions in the IEC60079-14 installation standard on the type of lamps…

Read More

System of earthing arrangements

Earthing arrangements determine how fault currents flow and are a key part of safe electrical installations in hazardous areas. Electrical earthing or circuit protective conductors (CPC) Conductors installed to provide a low impedance path for the current which flows under fault…

Read More