Ex m encapsulation protects small components by enclosing them in a compound that keeps flammable gas away. The method of protection, encapsulation, is used mainly for smaller items of equipment such as solenoid coils and electronic components. Standards IEC 60079-18: 2009…
Principle and Construction
The encapsulation principle seals ignition sources inside a compound so an explosive atmosphere cannot reach them. Principle With this type of protection the encapsulant, typically a thermosetting epoxy resin or thermoplastic, elastomeric material, establishes a complete barrier between any surrounding flammable…
Levels of Protection
Encapsulation levels of protection ma, mb and mc define how many faults Ex m equipment can tolerate and where it may be used. Encapsulated equipment may be manufactured with EPL ‘ma’, mb’ or ‘mc’. ‘ma’ – must not be capable of…