Rectified Power SystemsBuilt for outdoor, high-power and harsh duty.
An oil-immersed rectifier keeps the transformer windings and power electronics sealed from humidity, dust and salt air, for outdoor and high-power installations.
Electronically controlled thyristor rectifiers, oil- and oil-/water-cooled design
This type of rectifier distinguishes itself by its robust design (high protection class) and high operational reliability. All power components are oil-cooled (IP 54). Control and regulation are built in a separate switch cabinet.
System OverviewWhy choose an oil-immersed rectifier
- High operational safety
- Low maintenance requirements
- Robust design for aggressive environments
- High protection class
How an oil-immersed rectifier works
Oil-immersed rectifiers place the transformer and rectifier stack in a sealed, oil-filled tank. The oil carries heat away from the windings and power semiconductors and keeps out moisture, dust and salt air, which is why this design suits outdoor and high-power installations.
Modern rectifier control
Every rectifier uses a modern logic controller for precise regulation.
- High-resolution TFT LCD screen
- Advanced monitoring with alerts by SMS or email
- Communication with other systems via Modbus, Profinet and more
Technical Data
- Mains voltage: 220 – 690V, 50 – 60 Hz, 3-phase
- DC voltage: 6 – 400 Volt
- DC current: 2000 – 80000 Ampere
- Regulation: current and voltage constant
- Control range: 0 – 100 %
- Regulation accuracy: ±1 %
- Efficiency: > 85 %
- Ripple: 5 – 7 % at max. rating (Reduction possible)
- Mode of operation: 100 % ED (Power-on time)
- Ambient temperature: + 35 °C (higher temp on request)
- Protection class: IP 20 to IP 54
Tell us what's possible.
Send us your load, supply voltage and location. An AZUVIA engineer will reply.