Rectified Power SystemsClean DC for indoor, safe-area installations.
This forced air-cooled rectifier range converts AC into precise DC for industrial loads installed in safe, ventilated rooms.
Electronically controlled thyristor rectifiers integrated in a robust steel frame housing with front and back door
AZUVIA forced air-cooled rectifiers use thyristor-controlled rectification in a ventilated steel cabinet, with fans drawing air across the transformer and heat sinks. They are the simplest and most economical choice for indoor, safe-area installations such as engine rooms, pump houses and electrical rooms.
System OverviewWhy choose an air-cooled rectifier
- Environmentally-friendly
- Compact design
- Low-wear control
- High control precision
- High control speed
- Maintenance-friendly assembly
- Low maintenance requirement
How an air-cooled rectifier works
Forced air cooling suits clean, dry rooms with a stable ambient temperature. Where the air is humid, salty or dusty, an oil-immersed or water-cooled design is usually the better choice.
Modern rectifier control
Every rectifier uses a modern logic controller for precise regulation.
- High-resolution TFT LCD screen
- Advanced monitoring with alerts by SMS or email
- Communication with other systems via Modbus, Profinet and more
Models
Customised Transformer Rectifier
- Mains voltage: 220 – 690V, 50 – 60 Hz, 3-phase
- DC voltage: 6 – 400 Volt
- DC current: 2000 – 80000 Ampere
- Regulation: current and voltage constant
- Control range: 0 – 100 %
- Regulation accuracy: ±1 %
- Efficiency: > 85 %
- Ripple: 5 – 7 % at max. rating (Reduction possible)
- Mode of operation: 100 % ED (Power-on time)
- Ambient temperature: + 35 °C (higher temp on request)
- Protection class: IP 20 to IP 54
PS1K Transformer Rectifier
- Mains voltage: 440V, 60 Hz, 3-phase
- DC voltage: 15 Volt
- DC current: 440 Ampere
- Regulation: Current constant
- Control range: 0 – 100 %
- Regulation accuracy: ±1 %
- Efficiency: > 85 %
- Ripple: 5 – 7 % at max. rating (Reduction possible)
- Mode of operation: 100 % ED (Power-on time)
- Ambient temperature: + 35 °C (higher temp on request)
- Protection class: IP 44
PS3K Transformer Rectifier
- Mains voltage: 440V, 60 Hz, 3-phase
- DC voltage: 45 Volt
- DC current: 440 Ampere
- Regulation: Current constant
- Control range: 0 – 100 %
- Regulation accuracy: ±1 %
- Efficiency: > 85 %
- Ripple: 5 – 7 % at max. rating (Reduction possible)
- Mode of operation: 100 % ED (Power-on time)
- Ambient temperature: + 35 °C (higher temp on request)
- Protection class: IP 44
PS6K Transformer Rectifier
- Mains voltage: 440V, 60 Hz, 3-phase
- DC voltage: 75 Volt
- DC current: 440 Ampere
- Regulation: Current constant
- Control range: 0 – 100 %
- Regulation accuracy: ±1 %
- Efficiency: > 85 %
- Ripple: 5 – 7 % at max. rating (Reduction possible)
- Mode of operation: 100 % ED (Power-on time)
- Ambient temperature: + 35 °C (higher temp on request)
- Protection class: IP 44