# Power Requirements

Electrochlorination power consumption follows directly from the DC voltage and current needed for the required hypochlorite output.

Having determined the voltage and amperage requirements for the required productive capacity the DC power requirement is then known.

The simple result is :-

kWh =  Volts x Amps/h
 1000

kWh/kg = kWh / Kg/h NaOCl

A supplier would be able to provide more comprehensive power consumption per kg/h taking ancillary plant consumption and efficiencies into account. The main variable between suppliers however will be reflected in the DC kWh/kg quoted.

## Comparing electrochlorination power consumption

Once the DC voltage and current are known, the DC power follows directly: kilowatts equal volts multiplied by amps, divided by 1000. Dividing that power by the hourly hypochlorite output gives the specific energy, usually quoted in kWh per kg of chlorine equivalent. This figure is the fairest way to compare electrolysers from different suppliers.

However, DC energy is only part of the story. Rectifier losses, booster pumps, degassing blowers and dosing pumps all add to the total electrochlorination power consumption. A complete comparison therefore asks each supplier for both the DC figure and the overall AC consumption at the same output and seawater conditions.

Seawater temperature and salinity change cell voltage, so the specific energy also changes through the year. In addition, ageing electrode coatings raise voltage over time. As a result, a design margin is sensible. For the current side of the calculation, see [DC current requirement](/kb/process-chemistry/basics-on-current-requirement/); for the equipment that supplies it, see AZUVIA [rectified power systems](/product/powersys/). Energy-efficient converter design is covered by [IEC](https://www.iec.ch/) standards.