# Hydrogen Effect

The hydrogen effect describes how gas bubbles produced in electrolysers raise the resistance of the electrolyte and the voltage needed.

Hydrogen evolved during electrolysis of a brine solution will be proportional to the weight of NaOCl being produced and progressively increasing as the electrolyte passes through the electrolysis cells.

As the volume of hydrogen proportionally increases it has the effect of increasing the apparent electrical resistivity of the electrolyte, consequently requiring a higher than would otherwise be anticipated voltage to drive the DC current.

To minimise the effect of the Hydrogen maintaining a pressure within the Electrolysers as close to the design operating pressure as is reasonable will minimise the effect. The higher the operating pressure the lower the volume of the Hydrogen in relation to the volume of the carrier stream, and subsequently a lesser impact on the resistivity.

For large (e.g. >=50kg/h) electrolysers to operate efficiently in series the Hydrogen could be subject to hydrocyclone interstage degassing between electrolysers. This is removing the Hydrogen from the discharge of one Electrolyser before the carrier stream is introduced to the next Electrolyser in the series. This is necessary to minimise the voltage requirement by minimising the hydrogen effect on the electrolyte resistivity.

## Reducing the hydrogen effect

Every kilogram of chlorine produced also produces hydrogen, roughly 0.3 normal cubic metres of gas. In a long electrolyser train, these bubbles accumulate from one cell to the next. Because gas does not conduct, the electrolyte becomes more resistive, so the rectifier must supply a higher voltage to drive the same current. This is the hydrogen effect.

Designers use two main tools to limit it. First, operating the cells at a moderate back-pressure compresses the bubbles, so they take up less of the flow. Second, large systems can remove hydrogen between electrolysers, for example with hydrocyclones, before the stream enters the next cell. Both measures lower cell voltage and therefore power consumption.

Hydrogen also has to be handled safely after the last cell. Read [hydrogen degassing](/kb/main-equipment-items/basics-on-hydrogen-degassing-management/) to see how degas tanks and air blowers keep the gas below its lower explosive limit, and [electrolyser area classification](/kb/main-equipment-items/basics-on-electrolyser-area-classification/) for its effect on zoning. Equipment for hazardous areas, such as [ECHLORX](/product/ec/echlorx/), is certified under the [IECEx scheme](https://www.iecex.com/).