# Protective Gas

The protective gas keeps flammable gas out of a pressurised enclosure, so its source and quality are critical.

**The protective gas is normally air,** but for certain applications may be an inert gas such as nitrogen.

When air is the protective gas, it may be provided **from a safe area** by a motor driven fan or

compressor, or from storage cylinders. Sometimes air is drawn from a Zone 2 area, with gas

detectors fitted to alarm at a level well below the LEL. Air from Zone 0 or Zone 1 is not permitted

under any circumstances! **The air must not be oxygen enriched.**

The protective gas must be non-toxic and free from contaminants such as moisture, oil, dust, fibres,

chemicals. And other contaminants which could jeopardise the safe operation.

The temperature of the safe gas entering the inlet duct should not exceed 40°C unless allowed for in

the marking on the pressurised enclosure. A duplicate safe gas supply may be necessary if, on loss of

pressure, it would be dangerous to de-energise the equipment.

When an inert gas such as nitrogen is used as the protective gas and personnel can gain access to

enclosures, it is essential that doors/covers are fitted with warning labels since there is a danger of

asphyxiation. Doors should also be fitted with suitable locks.

## Choosing the protective gas

Air is the usual protective gas because it is free and safe to breathe. It must, however, come from a reliable source. A fan drawing from a safe area is ideal, while air from Zone 2 is only acceptable with gas detection that alarms well below the lower explosive limit. Instrument air from a compressor is common offshore, provided it is clean and dry.

Nitrogen is used where air is unsuitable, for example in analyser houses with oxygen-sensitive equipment. Because nitrogen can cause asphyxiation without warning, enclosures large enough to enter need warning labels and locks. In every case, check that the gas is free of oil, moisture and dust, and that its inlet temperature stays within the marked limit.

Where switching off on loss of pressure would be dangerous, a duplicate protective gas supply keeps the enclosure safe. For more detail, read [pressurisation ducts](/kb/pressurisation-ex-p/basics-on-ducts/) and [purging](/kb/pressurisation-ex-p/basics-on-purging/). The requirements are set out in IEC 60079-2, published by [IEC](https://www.iec.ch/).