# Temperature Limits

Pressurisation temperature limits decide the temperature class of a pressurised enclosure and its internal components.

#### **Type px or type py pressurisation**

The temperature class shall be based on the higher of the hottest external surface of the enclosure or the hottest internal component surface.

Internal components may exceed the enclosure T-class if the enclosure is marked with the time for them to cool to the T-class.

#### **Type pz pressurisation**

The temperature class shall be based on the hottest external surface of the enclosure, taking into account internal Ex equipment remaining energised in the absence of over-pressure.

## Applying pressurisation temperature limits

Temperature class is about the hottest surface that flammable gas could touch. With px and py pressurisation, gas is kept out while the enclosure is pressurised, but it could enter if pressure is lost. Therefore the temperature class must cover hot internal parts as well as the outside surface, unless they cool down before gas can reach them.

That is why some enclosures are marked with a cool-down time. After the supply is switched off, the door must stay closed for that time, so that internal surfaces fall below the T class before the enclosure is opened or loses protection. Type pz works differently: the temperature class is based on the external surface, taking into account any internal equipment that stays energised.

When selecting equipment, compare the marked temperature class with the ignition temperature of the gases present. For related topics, read [types of pressurisation](/kb/pressurisation-ex-p/basics-on-types-of-pressurisation-epl/) and [classification of gases](/kb/general-principles/classification-gases-vapour/). The rules are set out in IEC 60079-2, published by [IEC](https://www.iec.ch/).