# Powder filling (Ex q / EEx q)

Ex q powder filling protection surrounds ignition sources with fine granules so they cannot ignite the surrounding atmosphere.

The explosion protection concept powder filling is used in applications such as capacitors and ballast units in Increased Safety Ex ‘deq’ lighting fittings, and in telecommunicators equipment.

## **Standards**

| Current constructional standards |  |
| --- | --- |
| IEC 60079-5: 2007 BS EN 60079-5: 2007 | Explosive Atmospheres – Part 5: Equipment Protection by Powder filling ‘q’ |
| Older standards |  |
| BS EN 50017: 1998 | Powder filling ‘q’ |
| BS 5501-2: 1977 | Powder filling ‘q’ |
| Codes of Practice |  |
| BS 5354: Part 9: 1979 (Withdrawn) | Installation and maintenance requirements for electrical equipment with type of protection ‘q’ sand filled equipment |

**Note:** Since BS EN60079-14 and BS EN60079-17 do not provide selection, installation, inspection and maintenance requirements for powder filled equipment, in the UK BS 5345: Part 9 remains the only reference for guidance in these areas for the present

## **Definition**

‘A type protection in which the parts capable of igniting an explosive gas atmosphere are fixed in position and completely surrounded by a filling material to prevent the ignition of an external explosive atmosphere.’

**Zone of Use: 1 & 2**

![powder filling ex q /  exx q](https://www.azuvia.co/wp-content/uploads/2026/11/powder-filliing.png)

## Using Ex q powder filling equipment

Ex q powder filling is rarely seen as a stand-alone product. Instead, it usually protects a component inside other equipment, such as the capacitor in a fluorescent light fitting or part of a communication device. As a result, users mostly meet it through the combined marking on the finished product, for example Ex deq.

Installation and maintenance follow the manufacturer's documentation. Powder-filled modules should not be opened on site, because disturbing the filling can create gaps that defeat the protection. In addition, check that enclosures, seals and any breathing devices are intact during inspection, and replace damaged modules with identical certified parts.

Remember the certification rules. A component with a U certificate is only certified for use within a fully certified assembly. For background, read [powder filling principle](/kb/powder-filling-ex-q-eex-q/basics-on-powder-filling-principle/) and [powder filling construction](/kb/powder-filling-ex-q-eex-q/basics-on-powder-filling-construction/). Equipment of this kind is certified through the [IECEx scheme](https://www.iecex.com/).