# Construction

Powder filling construction rules set the IP rating, filling material and clearances needed for Ex q equipment.

The minimum ingress protection for this type of protection is IP54, but equipment constructed to provide IP55 must be fitted with a breathing device.

Where use is in clean, dry environments only (equipment certified with the suffix ‘X’). the ingress protection may be reduced to IP43.

The size of granules for the filling material must be within a range specified in the standards, and the filling material is required to withstand an electric strength test where the leakage current must not exceed one microamp.

The standards specify minimum clearance distances between electrically conducting parts and insulated components or the inner surface of the enclosure wall.

Only Ex “q” equipment having a complete certificate shall be installed in accordance with the manufacturer’s documentation.

Ex “q” enclosure or component that has only component certificate (marked “U”) is not allowed to be installed in hazardous area unless it is part of an assembly of components in an equipment that has a full Ex certificate with the “X” and equipment label has full “Ex” marking including temperature class.

## Checking powder filling construction

Powder filling construction depends on three things: a tight enclosure, the right filling material and enough depth of filling around every live part. The minimum IP54 rating keeps moisture out, because damp powder would lose its insulating and flame-quenching properties. Where an enclosure is sealed to IP55, a breathing device prevents pressure changes from drawing in water.

The filling itself, usually quartz sand or glass beads, must fall within a specified grain size and pass an electric strength test. In addition, the standard sets minimum distances between live parts and the enclosure walls, so a flame cannot reach the surface of the powder.

For users, the practical rules are simple. Do not open powder-filled units in the field, check that seals and breathers are intact, and only install items with a full certificate. For the theory, read [powder filling principle](/kb/powder-filling-ex-q-eex-q/basics-on-powder-filling-principle/), and for applications see [Ex q powder filling](/kb/powder-filling-ex-q-eex-q/basics-on-powder-filling/). The construction rules are in IEC 60079-5 from [IEC](https://www.iec.ch/).