title: Sea Water Supply System
description: The seawater supply system feeds the electrochlorination package and has a direct effect on its pressure, flow and reliability. Having established the importance of the seawater supply utility analysis lack of information regarding the pressures at which the supply utility…
url: "https://www.azuvia.co/kb/main-equipment-items/basics-on-seawater-supply-system/"
updated: "2026-11-07"
category: Electrochlorination Basics / Main Equipment Items
---

# Sea Water Supply System

The seawater supply system feeds the electrochlorination package and has a direct effect on its pressure, flow and reliability.

Having established the importance of the seawater supply utility analysis lack of information regarding the pressures at which the supply utility will be provided will also be a design factor the Electrochlorination Package supplier.

The mass balance through the ECP is generally dependent on a consistent stable seawater supply pressure which in most instances it is not possible to provide as a utility. Generally seawater utilities are bled from the high volume variable low pressure sources and as such will require seawater booster pumps to achieve the required operating pressure for the ECP.

The ECP supplier will be faced with two difficulties in this area as the supply utility will also probably have been subject only to coarse screening. This is inadequate for electrolyser installations wherein flow paths will be narrow multiple channels necessitating prior screening to <1000µm.

Ideally automatic backwashing strainers will be utilised upstream of seawater booster pumps and pressure control equipment, should the minimum utility supply pressure be inadequate for this purpose then the strainers will be installed down stream of this equipment for which a change to the supply specification may not be ideal and the booster pumps up rated to accommodate the back flush volumetric requirement.

## Designing the seawater supply system

Most electrochlorination problems start upstream of the electrolyser. A good seawater supply system therefore needs a stable pressure, enough flow for the electrolysers and any backwash, and water that is free of debris. Because utility seawater is often taken from large, low-pressure headers, a booster pump is usually needed to hold the package at its design pressure.

Screening matters just as much. Electrolysers have narrow flow channels, so the supply should be strained to below 1000 µm before it reaches the cells. Automatic backwashing strainers are the usual choice, because they clean themselves without stopping the flow. In addition, the backwash volume must be added to the pump duty, otherwise the cells may be starved of water during each flush.

When you prepare a specification, state the minimum and maximum supply pressure, the expected debris load and the seawater temperature range. As a result, the supplier can size the pumps and strainers correctly. For the electrolysers that follow, see our guide to [seawater electrolysers](/kb/main-equipment-items/basics-on-electrolysers/), or our [ECHLOR seawater electrochlorination](/product/ec/echlor/) range. Fouling control on ships and offshore units is also covered by the [IMO biofouling guidance](https://www.imo.org/en/OurWork/Environment/Pages/Biofouling.aspx).