# Electrolyser Installation

Electrolyser installation needs care because the plastic materials in each cell limit the pressure and temperature it can take.

This is an area where the materials of construction have an important impact.

As stated previously there is a requirement for the use of plastic materials within the construction of an electrolyser assembly. The use of this material will have an impact upon the pressure and temperature limits of the installation which has to be taken into account.

The main considerations are whether the installation will be indoors or outdoors typically under a shade. Solar gain or freezing is not usually problematical for an outdoor installation in operation as the seawater flow is relatively massive compared to the Electrolyser mass and the process heat dissipation, solar gain or freezing ambient temperatures.

It is conventional however to have part of the system idle due to a plant redundancy. In this instance solar gain and freezing are problematical unless the idle electrolysers are drained or alternative protection methods are employed, e.g. trace heating.

## Practical points for electrolyser installation

Electrolysers combine titanium electrodes with plastic housings, flanges and pipework. Plastics lose strength as temperature rises, so every electrolyser installation must respect the combined pressure and temperature limits of these materials. That limit also affects the design of the seawater supply and the hydrogen degassing system downstream.

Location is the next decision. Indoor installation protects cells from sun and weather, while outdoor installation under a shade roof is common offshore and on coastal sites. In operation, the large seawater flow keeps cell temperatures stable. However, standby electrolysers sit full of stagnant water, so they can overheat in direct sun or freeze in cold climates. Draining idle cells, or fitting trace heating, avoids damage.

Finally, leave room for maintenance. Cells need to be inspected, acid washed or replaced, so access, lifting points and isolation valves should be planned from the start. Because hydrogen is present, the area around the cells is also classified; read [electrolyser area classification](/kb/main-equipment-items/basics-on-electrolyser-area-classification/) for details. Our [ECHLOR electrolysers](/product/ec/electrolysers/) are designed with these needs in mind, and hazardous-area equipment can be certified under the [IECEx scheme](https://www.iecex.com/).