# Mechanical Strength

Mechanical strength tests prove that Ex equipment keeps its protection after impacts and drops.

## Impact tests

As well as having the degree of ingress protection called for in the various construction standards, enclosures for electrical equipment must pass an impact test.

In this test, a test weight of 1kg with an impact head of hardened steel, in the form of a 25mm hemisphere, is dropped onto the completely assembled equipment from a height ‘h’.

At the end of the test, there must not be enough damage to invalidate the type of protection, IP code etc.

The height ‘h’ in metres, is given in the standards and varies with the equipment Group and the risk of mechanical impact (high or low). The standard details the two levels of impact resistance appropriate to high and low risk of impact. If the equipment is only suitable for low impact, the certificate is suffixed ‘X’ to signify special conditions of use apply (See Unit 2).

## Drop tests

In addition to the impact test, portable (hand-held) electrical or electronic equipment must be subjected to a drop test, in which it is dropped at least four times on to a horizontal concrete surface from a height of one metre.

Again the acceptance criterion is that there is not enough damage to invalidate the type of protection, IP code etc.

## Why mechanical strength matters

Explosion protection only works if the enclosure stays intact. A cracked window, dented cover or broken gland can open a path for gas or water, defeating the protection. Mechanical strength tests prove that equipment can survive the knocks it is likely to meet in service.

When the risk of impact is low, equipment can be tested at a lower energy, but its certificate then carries an X, meaning special conditions of use apply. In practice, that equipment must be installed where it is protected from impact, for example behind a guard or away from walkways and lifting areas. Always read the special conditions before installation.

Portable equipment faces an extra drop test, because it is likely to be dropped. During inspection, look for impact damage, cracked lenses and damaged glands, and replace damaged parts. For related topics, read [IP code](/kb/general-principles/basics-on-ingress-protection/) and [Ex product certification](/kb/standards-certification-and-marking/basics-on-product-certification/). Test requirements are in IEC 60079-0, published by [IEC](https://www.iec.ch/).