title: Levels of Protection
description: Encapsulation levels of protection ma, mb and mc define how many faults Ex m equipment can tolerate and where it may be used. Encapsulated equipment may be manufactured with EPL ‘ma’, mb’ or ‘mc’. ‘ma’ – must not be capable…
url: "https://www.azuvia.co/kb/encapsulation-ex-m-eex-m/basics-on-levels-of-protection-encapsulation/"
updated: "2026-11-07"
category: Explosion Proof Basics / Encapsulation (Ex m / EEx m)
---

# Levels of Protection

Encapsulation levels of protection ma, mb and mc define how many faults Ex m equipment can tolerate and where it may be used.

Encapsulated equipment may be manufactured with EPL ‘ma’, mb’ or ‘mc’.

‘ma’ – must not be capable of causing ignition:

- In normal operation and installation conditions
- Any specified abnormal conditions
- In defined failure conditions

‘mb’ – must not be capable of causing ignition:

- In normal operation and installation conditions;
- In defined failure conditions

‘mc’ – must not be capable of causing ignition:

- During normal operation and installation conditions

#### Level of protection ‘ma’

- Has the highest integrity of protection.
- Remain safe with two internal countable faults.
- The working voltage at any point in the circuit shall not exceed 1 kV.
- May be used in areas requiring EPL ‘Ga’, ‘Gb’ and ‘Gc’ or Category 1,2 and 3.

#### Level of protection ‘mb’

- Remain safe with one internal countable faults.
- May be used in areas requiring EPL ‘Gb’ and ‘Gc’ or Category 2 and 3.

#### Level of protection ‘mc’

- May only used in areas requiring EPL ‘Gc’ or Category 3.

## Choosing between encapsulation levels of protection

The three encapsulation levels of protection trade fault tolerance against cost. Level ma survives two countable faults and limits working voltage to 1 kV, so it can be used even where EPL Ga is required. Level mb survives one fault and suits EPL Gb, which normally means Zones 1 and 2. Level mc only covers normal operation, so it is limited to EPL Gc and Zone 2.

In practice, choose the level from the area classification drawing. If the drawing shows the required EPL, select equipment that meets or exceeds it. If it only shows zones, use the usual mapping of Zone 0 to Ga, Zone 1 to Gb and Zone 2 to Gc, unless a risk assessment says otherwise.

Remember too that encapsulated parts cannot be repaired; a damaged module is replaced as a whole. For the construction behind these levels, read [encapsulation principle](/kb/encapsulation-ex-m-eex-m/basics-on-encapsulation-principle-construction/) and [Ex m encapsulation](/kb/encapsulation-ex-m-eex-m/basics-on-encapsulation/). The levels are defined in IEC 60079-18, published by [IEC](https://www.iec.ch/).